QUESTIONS ABOUT INFRARED?
Call 845-641-5482 and find out how Infrared
can help your business!

This overheated connection measured in excess of 200 degrees!
Corroded fuse clip temination overheats the fuse
Blower door test reveals poor air sealing around the through wall trim place of a pellet stove chimney.
Loose connections cause overheated wires conections and buss bar
Condensate drain on air conditioner evaporator coil shows correct flow, no sign of blockage, not cause of leak.
Infrared Image of water leak in ceiling from Air conditioner
SUV tire close up. Delta T for this image was less than than 3 degrees F across the tire surface
Misplaced insulation near top of cathedral ceiling shows attic heat in summer.
This switch has an internal connection problem
Infrared image shows a hot connection on a breaker caused by a loose screw
Heat loss from internal framing attachment points
Fuse clip problem
Infrared electrical inspection finds overheating connector
Cold air infiltration into wall cavity and ceiling, now we know why the bedroom floor above was so cold.
Air infiltration between window and window frame
Infrared  image of a 1/8 hp pump motor
Portable air conditioner exhaust duct not sealed properly and is blowing hot exhaust air (126F) back into the conditioned space!
Infrared image or missing CMU grout
Loose connection on "A" phase
Infrared Image Breaker showing signs of overheating
Infrared image of a bubble in the side wall of a car tire. The bubble is the dark oval shape after the letter "T"
Blower door shows how unsealed recessed lights leak air
Buss bars behind the breakers are overheating
Blocked drains allow water build up behind brick wall
Histogram of thermal profile
Infrared image of steam release on condensate line
Under floor radient heating colis
Air conditioner blower leaks air from unsealed plenum ductwork. Cold air is blowing air stream on horizontal rafter above unit
This overheating electrical connection was caused by a loose screw
Image of an Infrared electrical survey, phase A
Air infiltration - Worn weather stripping
Left Tire. Uneven temperature profile shows tire alignment issues.
Infrared wall grout inspection
Unsealed/un-insinuated recessed lights show attic heat. In winter these lights allow heat to escape into the attic.
One panel,multiple exceptions
Hot jumper wire on timer
Infrared image of  a Disconnect Switch with resistive contacts heating up
Water leak in window allowed moisture into the wall
Air infiltration - Missing door sweep. Cold air from adjacent unheated room coming in by baseboard heater.
Missing insulation in walls
All phases on this breaker are overloaded
Infrared CMU inspection - Infraed Imaging Services LLC
Infrared image shows grout in CMU wall
Infrared image of wet roof insulation -  Infrared Imaging Services LLC
Infrared image shows grout in CMU wall,
Hot AC server plug
Infrared scan of this Blockwall shows the grout missing from the third column behind the scaffold
Grout missing from this section of Blockall
Infrared roof inspection
Infrared scan of cement block wall shows grout placement and omissions
Infrared roof inspection of EPDM parapet wall - Infrared Imaging Services LLC
Infrared roof moisture survey
Infrared datacenter server racks
Roof moisture survey
First place image IR/Info 2010! Image of low slope roof , trapped moisture under membrain
Infrared roof inspection - Infraed imaging Services LLC
Infrared survey of cement block wall shows Grout placement
Infrared image of temperature profile down server row
Localized hot spot due to blocked air flow in Datacenter equipment rack
First place image IR/Info 2010! Image of CMU wall, missing grout shows as darkened areas
400 A breaker powering server racks with a bad termination is getting warm
Moisture trapped under 2 layers of Asphalt roof. Roof is bubbled and has Alligator pattern
Infrared image of faulty motor in  server rack cooling fan
Image shows wet bat insulation on underside (interior)of flat leaky metal warehouse roof
Infrared finds roof moisture
Localized heating on AC plug in Data center equipment rack
Infrared image of grout in CMU wall
Hot power supply in computer server rack
Infrared image showing temperature profile across server rack

The Stack effect and why your building has a draft.

Drafts are caused by an air pressure imbalance. As warmed air rises to the upper levels of the building, it creates a positive pressure and leaks out of the gaps and cracks in the building's envelope. At the same time a negative pressure is created at the lower levels actively sucking in outside air to replace what leaked out at the top. In the Northeast this replacement air is cold and dry in Wintertime and hot and humid in Summertime. We call the replacement air a "Draft" and it makes us uncomfortable and wastes energy. This natural air circulation is called the "Stack Effect", the taller the building and the stronger the temperature gradient from top to bottom the stronger the effect is. It's costing you money right now and Infrared show you where the gaps in the building are.!

Warm Air Rises

Copyright © 2008-2014, Infrared Imaging ServicesLLC. All rights reserved.
The copying, reproduction or distribution of these images and text by any means without written approval is prohibited.
Site Designed by Kyle Baker Design

Areas We Service

Rockland County - New City

Located in New City, NY, Below is a partial list of towns Infrared Imaging Services LLC: New City, Nyack, Piermont, Haverstraw, Stony Point, Nanuet, Pearl River, Orangeburg, Chestnut Ridge, Wesley Hills, Pomona, Suffern, Airmont, Sloatsburg

Orange County - New York

Tuxedo, Goshen, Monroe, Central Valley, New Windsor, Newburgh, West Point, fort Montgomery, Middletown, Florida, Warwick, Port Jervis

Westchester County - New York

Tarrytown, Dobbs Ferry, Elmsford, White Plains, Ardsley, Yonkers, Mount Vernon, New Rochelle, Bronxville, Eastchester, Scarsdale, Mamaroneck, Harrison, Port Chester, Valhalla, Hawthorne Pleasantville, Armonk, Chappaqua, Croton, Mount Kisco, Bedford, Buchanan, Yorktown Heights, Pound Ridge, Lewisboro, south Salem, North Salem, Golden’s Bridge, Yorktown Heights

Bergen County - New Jersey

Ramsey, Mahwah, Upper Saddle River, Saddle River, Montvale, Park Ridge, Old Tappan, Northvale, Alpine, Closter, Norwood, Westwood Washington Township, Waldwick, Wyckoff, Ridgewood, Paramus, New Milford, Tenafly, Englewood Cliffs, Englewood, Hackensack, Teaneck, Fairlawn, Hawthorne

New York City - New York

Manhattan, Brooklyn, Queens, Bronx, Staten Island