QUESTIONS ABOUT INFRARED?
Call 845-641-5482 and find out how Infrared
can help your business!

Air infiltration between window and window frame
Infrared Image Breaker showing signs of overheating
Unsealed/un-insinuated recessed lights show attic heat. In winter these lights allow heat to escape into the attic.
Hot jumper wire on timer
Left Tire. Uneven temperature profile shows tire alignment issues.
Infrared  image of a 1/8 hp pump motor
Blocked drains allow water build up behind brick wall
Water leak in window allowed moisture into the wall
Air conditioner blower leaks air from unsealed plenum ductwork. Cold air is blowing air stream on horizontal rafter above unit
Missing insulation in walls
Cold air infiltration into wall cavity and ceiling, now we know why the bedroom floor above was so cold.
Fuse clip problem
Histogram of thermal profile
Portable air conditioner exhaust duct not sealed properly and is blowing hot exhaust air (126F) back into the conditioned space!
Condensate drain on air conditioner evaporator coil shows correct flow, no sign of blockage, not cause of leak.
Infrared image shows a hot connection on a breaker caused by a loose screw
Image of an Infrared electrical survey, phase A
Blower door test reveals poor air sealing around the through wall trim place of a pellet stove chimney.
This overheating electrical connection was caused by a loose screw
Air infiltration - Worn weather stripping
Under floor radient heating colis
Infrared image of steam release on condensate line
Infrared image or missing CMU grout
Infrared image of a bubble in the side wall of a car tire. The bubble is the dark oval shape after the letter "T"
Blower door shows how unsealed recessed lights leak air
Corroded fuse clip temination overheats the fuse
Infrared electrical inspection finds overheating connector
SUV tire close up. Delta T for this image was less than than 3 degrees F across the tire surface
Infrared Image of water leak in ceiling from Air conditioner
Infrared image of  a Disconnect Switch with resistive contacts heating up
This switch has an internal connection problem
Buss bars behind the breakers are overheating
One panel,multiple exceptions
Infrared wall grout inspection
Misplaced insulation near top of cathedral ceiling shows attic heat in summer.
Heat loss from internal framing attachment points
Air infiltration - Missing door sweep. Cold air from adjacent unheated room coming in by baseboard heater.
Loose connection on "A" phase
Loose connections cause overheated wires conections and buss bar
This overheated connection measured in excess of 200 degrees!
All phases on this breaker are overloaded
Hot AC server plug
Infrared image of grout in CMU wall
First place image IR/Info 2010! Image of low slope roof , trapped moisture under membrain
Infrared scan of cement block wall shows grout placement and omissions
Grout missing from this section of Blockall
Infrared image shows grout in CMU wall
Hot power supply in computer server rack
Infrared image of wet roof insulation -  Infrared Imaging Services LLC
Infrared roof moisture survey
Infrared image of temperature profile down server row
Moisture trapped under 2 layers of Asphalt roof. Roof is bubbled and has Alligator pattern
400 A breaker powering server racks with a bad termination is getting warm
Infrared roof inspection
Infrared image of faulty motor in  server rack cooling fan
Infrared image showing temperature profile across server rack
Localized heating on AC plug in Data center equipment rack
Infrared scan of this Blockwall shows the grout missing from the third column behind the scaffold
Image shows wet bat insulation on underside (interior)of flat leaky metal warehouse roof
Infrared CMU inspection - Infraed Imaging Services LLC
First place image IR/Info 2010! Image of CMU wall, missing grout shows as darkened areas
Localized hot spot due to blocked air flow in Datacenter equipment rack
Infrared datacenter server racks
Infrared roof inspection of EPDM parapet wall - Infrared Imaging Services LLC
Infrared roof inspection - Infraed imaging Services LLC
Infrared survey of cement block wall shows Grout placement
Infrared image shows grout in CMU wall,
Roof moisture survey
Infrared finds roof moisture

The Stack effect and why your building has a draft.

Drafts are caused by an air pressure imbalance. As warmed air rises to the upper levels of the building, it creates a positive pressure and leaks out of the gaps and cracks in the building's envelope. At the same time a negative pressure is created at the lower levels actively sucking in outside air to replace what leaked out at the top. In the Northeast this replacement air is cold and dry in Wintertime and hot and humid in Summertime. We call the replacement air a "Draft" and it makes us uncomfortable and wastes energy. This natural air circulation is called the "Stack Effect", the taller the building and the stronger the temperature gradient from top to bottom the stronger the effect is. It's costing you money right now and Infrared show you where the gaps in the building are.!

Warm Air Rises

Copyright © 2008-2014, Infrared Imaging ServicesLLC. All rights reserved.
The copying, reproduction or distribution of these images and text by any means without written approval is prohibited.
Site Designed by Kyle Baker Design

Areas We Service

Rockland County - New City

Located in New City, NY, Below is a partial list of towns Infrared Imaging Services LLC: New City, Nyack, Piermont, Haverstraw, Stony Point, Nanuet, Pearl River, Orangeburg, Chestnut Ridge, Wesley Hills, Pomona, Suffern, Airmont, Sloatsburg

Orange County - New York

Tuxedo, Goshen, Monroe, Central Valley, New Windsor, Newburgh, West Point, fort Montgomery, Middletown, Florida, Warwick, Port Jervis

Westchester County - New York

Tarrytown, Dobbs Ferry, Elmsford, White Plains, Ardsley, Yonkers, Mount Vernon, New Rochelle, Bronxville, Eastchester, Scarsdale, Mamaroneck, Harrison, Port Chester, Valhalla, Hawthorne Pleasantville, Armonk, Chappaqua, Croton, Mount Kisco, Bedford, Buchanan, Yorktown Heights, Pound Ridge, Lewisboro, south Salem, North Salem, Golden’s Bridge, Yorktown Heights

Bergen County - New Jersey

Ramsey, Mahwah, Upper Saddle River, Saddle River, Montvale, Park Ridge, Old Tappan, Northvale, Alpine, Closter, Norwood, Westwood Washington Township, Waldwick, Wyckoff, Ridgewood, Paramus, New Milford, Tenafly, Englewood Cliffs, Englewood, Hackensack, Teaneck, Fairlawn, Hawthorne

New York City - New York

Manhattan, Brooklyn, Queens, Bronx, Staten Island