Left Tire. Uneven temperature profile shows tire alignment issues.
Loose connection on "A" phase
Air conditioner blower leaks air from unsealed plenum ductwork. Cold air is blowing air stream on horizontal rafter above unit
Fuse clip problem
Air infiltration - Missing door sweep. Cold air from adjacent unheated room coming in by baseboard heater.
Cold air infiltration into wall cavity and ceiling, now we know why the bedroom floor above was so cold.
Infrared image or missing CMU grout
Corroded fuse clip temination overheats the fuse
Infrared electrical inspection finds overheating connector
Histogram of thermal profile
Blower door test reveals poor air sealing around the through wall trim place of a pellet stove chimney.
Missing insulation in walls
Heat loss from internal framing attachment points
Loose connections cause overheated wires conections and buss bar
Air infiltration between window and window frame
Misplaced insulation near top of cathedral ceiling shows attic heat in summer.
Hot jumper wire on timer
Blocked drains allow water build up behind brick wall
SUV tire close up. Delta T for this image was less than than 3 degrees F across the tire surface
Infrared wall grout inspection
Blower door shows how unsealed recessed lights leak air
Infrared image of a bubble in the side wall of a car tire. The bubble is the dark oval shape after the letter "T"
Buss bars behind the breakers are overheating
This switch has an internal connection problem
Infrared Image of water leak in ceiling from Air conditioner
Image of an Infrared electrical survey, phase A
One panel,multiple exceptions
Portable air conditioner exhaust duct not sealed properly and is blowing hot exhaust air (126F) back into the conditioned space!
Condensate drain on air conditioner evaporator coil shows correct flow, no sign of blockage, not cause of leak.
Infrared image shows a hot connection on a breaker caused by a loose screw
This overheating electrical connection was caused by a loose screw
Infrared Image Breaker showing signs of overheating
All phases on this breaker are overloaded
Unsealed/un-insinuated recessed lights show attic heat. In winter these lights allow heat to escape into the attic.
Air infiltration - Worn weather stripping
Water leak in window allowed moisture into the wall
Under floor radiant heating colis
This overheated connection measured in excess of 200 degrees!
Infrared image of steam release on condensate line
Infrared image of  a Disconnect Switch with resistive contacts heating up
Infrared  image of a 1/8 hp pump motor
Infrared image shows grout in CMU wall,
Infrared scan of this Blockwall shows the grout missing from the third column behind the scaffold
Image shows wet bat insulation on underside (interior)of flat leaky metal warehouse roof
Localized heating on AC plug in Data center equipment rack
Infrared CMU inspection - Infraed Imaging Services LLC
400 A breaker powering server racks with a bad termination is getting warm
Hot AC server plug
Roof moisture survey
Infrared survey of cement block wall shows Grout placement
Infrared image of temperature profile down server row
Infrared scan of cement block wall shows grout placement and omissions
Infrared image shows grout in CMU wall
Infrared roof inspection
First place image IR/Info 2010! Image of CMU wall, missing grout shows as darkened areas
Infrared image of faulty motor in  server rack cooling fan
Infrared roof moisture survey
Infrared datacenter server racks
Moisture trapped under 2 layers of Asphalt roof. Roof is bubbled and has Alligator pattern
Infrared image of grout in CMU wall
Infrared finds roof moisture
Infrared image of wet roof insulation -  Infrared Imaging Services LLC
Infrared roof inspection of EPDM parapet wall - Infrared Imaging Services LLC
Infrared roof inspection - Infraed imaging Services LLC
Infrared image showing temperature profile across server rack
First place image IR/Info 2010! Image of low slope roof , trapped moisture under membrain
Hot power supply in computer server rack
Localized hot spot due to blocked air flow in Datacenter equipment rack
Grout missing from this section of Blockall

Infrared image shows Nitrogen blanket visible above oil level a on this power plant output transformer

Infrared image shows Nitrogen blanket visible above oil level a on this power plant output transformer - Infrared Imaging Services LLC

Infrared image shows Nitrogen blanket visible above oil level a on this power plant output transformer

Copyright © 2008-2016, Infrared Imaging ServicesLLC. All rights reserved.
The copying, reproduction or distribution of these images and text by any means without written approval is prohibited.
Site Designed by Kyle Baker Design

Areas We Service

Rockland County - New City

Located in New City, NY, Below is a partial list of towns Infrared Imaging Services LLC: New City, Nyack, Piermont, Haverstraw, Stony Point, Nanuet, Pearl River, Orangeburg, Chestnut Ridge, Wesley Hills, Pomona, Suffern, Airmont, Sloatsburg

Orange County - New York

Tuxedo, Goshen, Monroe, Central Valley, New Windsor, Newburgh, West Point, fort Montgomery, Middletown, Florida, Warwick, Port Jervis

Westchester County - New York

Tarrytown, Dobbs Ferry, Elmsford, White Plains, Ardsley, Yonkers, Mount Vernon, New Rochelle, Bronxville, Eastchester, Scarsdale, Mamaroneck, Harrison, Port Chester, Valhalla, Hawthorne Pleasantville, Armonk, Chappaqua, Croton, Mount Kisco, Bedford, Buchanan, Yorktown Heights, Pound Ridge, Lewisboro, south Salem, North Salem, Golden’s Bridge, Yorktown Heights

Bergen County - New Jersey

Ramsey, Mahwah, Upper Saddle River, Saddle River, Montvale, Park Ridge, Old Tappan, Northvale, Alpine, Closter, Norwood, Westwood Washington Township, Waldwick, Wyckoff, Ridgewood, Paramus, New Milford, Tenafly, Englewood Cliffs, Englewood, Hackensack, Teaneck, Fairlawn, Hawthorne

New York City - New York

Manhattan, Brooklyn, Queens, Bronx, Staten Island